Precautions for using CO2 incubator?
CO2 incubators are widely used in the research and production of microbiology, medicine, pharmaceuticals, environmental protection, food, animal husbandry and other scientific fields. Because there are many advantages in using it. So it is very popular with everyone. Let's talk about the precautions for using a CO2 incubator?

The CO2 incubator adopts door temperature control, which can effectively prevent dew condensation on the off-duty door in the incubator. So that its box has been equipped with a special pressure reducing valve for carbon dioxide incubators. It is mainly used for tissue culture and the cultivation of some special microorganisms. Of course, it also all uses artificial methods to create an artificial environment for the growth and reproduction of microorganisms, cells, bacteria, and viruses in the incubator when it is working. If you don't know much about this device yet. I suggest you all to check it out here. Moreover, the power switch cannot be turned on before the CO2 incubator is filled with water, otherwise the heating element will be damaged. Except in these places that need attention. What you also need to know is that after the incubator has been in operation for several months, the water in the water tank may decrease due to volatilization, so when it is working, it should add water when the low water level indicator light is on. It is recommended that the staff also open the overflow pipe at this time, use a funnel to connect the rubber tube to add water from the water injection hole to make the low water level indicator light go off, and then use the CO2 incubator to measure and add water after all these are completed, and then block the overflow hole.
The CO2 incubator also needs to pay attention to many matters when using it. Other than what I have said for you. There are also some issues that need to be paid attention to in other places. For example, it is corrected at saturated humidity, so the humidification pan must always be filled with sterile water. When the displayed temperature of the CO2 incubator exceeds the set temperature by 1°C, the over-temperature alarm indicator light is on and a sharp alarm sound is issued. At this time, the problem we must pay attention to is that the power should be turned off for 30 minutes; Overheating, what you have to do is turn off the power and report to the maintenance personnel. Minimize the time you spend opening glass doors. For CO2 incubator, it is necessary to use the random special wrench to disassemble and assemble the bracket shield in the working room, and excessive force shall not be allowed. At the same time, the staff are also reminded here not to turn the incubator upside down, and at the same time, do not lift the door to avoid deformation of the door. And when you clean the working chamber of the incubator, do not collide with parts such as sensors and stirring motor wind wheels. The products here are exported to more than 30 countries and regions such as Europe and America, and domestic sales offices and maintenance centers have been established in more than ten provinces to provide users with convenient and thoughtful services.
The content of the above article is the precautions for using the CO2 incubator introduced by the editor. If you didn't know it before, you can see it now. The next issue will also tell you about the knowledge points related to it. Remember to watch it.