News Center


The company's products are widely applicable in fields such as life sciences, healthcare, universities, electronics, chemical engineering, agriculture, metallurgy, biology, health and epidemic prevention, environmental protection, etc.


01

2022

-

12

Introduction to the main items of using CO2 incubator?


  With the continuous advancement of science and technology, all walks of life have also been greatly developed. The development prospects of CO2 incubators are also very good, so the demand continues to increase, and many manufacturers have also increased on the market. And as a manufacturer, it is necessary for us to tell you about the main items of using CO2 incubators here. Interested friends can take a look together.

 

CO2 incubator

 

  Before we use this CO2 incubator, we also have many problems with you, so if you want to use it better, you must understand some of its knowledge points. First of all, you need to know that CO2 incubators are widely used in the research and production of microorganisms, medicine, pharmaceuticals, environmental protection, food, animal husbandry and other scientific fields. It is an artificial environment in which microorganisms, cells, bacteria and viruses grow and reproduce in an incubator through artificial methods, such as controlling a certain temperature, humidity, gas, etc., and is also mainly used for tissue culture and some special cultures. microorganism. While it has many advantages, it also has many caveats. For example, the power switch cannot be turned on before it is filled with water, otherwise the heating element will be damaged. Or after several months of operation, the water in the tank may decrease due to volatilization. When the low water level light is on, add water. First open the overflow pipe, use a funnel to connect the rubber tube to add water from the water injection hole, make the low water level indicator go out, then add water by metering, and then block the overflow hole. The CO2 sensor is calibrated at saturated humidity, so the humidification pan is always filled with sterile water. Normally, the CO2 incubator should also be placed on a flat ground, and the environment should be clean and tidy, dry and ventilated; before use, each control switch should be in a non-working state, and the speed control knob should be placed in the small position.

  In addition, when using the CO2 incubator , it is also necessary to pay attention that when the displayed temperature exceeds the set temperature by 1°C, the over-temperature alarm indicator will light up and a sharp alarm will sound. At this time, the power should be turned off for 30 minutes; if it is turned on again, if the power switch is still overheated, please turn off the power and report to the maintenance personnel. Or when the cylinder pressure is lower than 0.2mpa, the cylinder should be replaced. Minimize the time you spend opening glass doors. If the CO2 incubator is not used for a long time, it is recommended to clear the water in the working room before closing it, and open the glass door for ventilation for 24 hours before closing it. It is also important not to collide with parts such as sensors and stirring motor rotors when cleaning the chamber. Or when disassembling the bracket cover in the studio, use the special wrench that comes with it, and don't use too much force. The CO2 incubator removes the water in the box before shipping. When releasing water, cover the rubber tube on the water outlet tightly so that the nozzle is lower than the instrument, take a light breath, put down the water tube, and the water will flow out by siphon. The shelves and humidification trays in the working room should also be taken out during transportation to prevent collisions from damaging the glass door.

  The above is about the " Main points of using CO2 incubator ". If you still don't understand, please call us. That's all for today's knowledge points, I hope it can help you. The next issue will bring more information about it.